World leaders of innovative solutions in fire detection and alarm systems. At this point, the optical smoke detector changes in to the alarm state. Mar 16, 2020 the apollo xp95 optical smoke detector includes a photodiode monitoring permanently the light pulse emitted by the internal led. Apollo smoke detector wiring diagram wiring diagram and. The apollo xp95 optical smoke detector uses an internal pulsing infrared led and a photodiode at an obtuse angle. It is apollos duty, as leading fire detection manufacturers, to adapt to these revised standards and develop smart devices that keep people safe from fire, every second of every day. The detector housing is identical to that of the ionisation detector but has an indicator led which is clear in quiescent state but produces red light in.
Optical smoke detectors incorporate a pulsing led located in a labyrinth within the housing of the detector. The detector housing shall be ul listed per ul 268a specifically for use in air handling systems. The xp95 optical smoke detector works using the light scatter principle and is ideal for applications where slowburning or smouldering fires are likely. Optical smoke detector product description coopers fire supply the apollo series 65 optical smoke detector 55000317. Apollo s65 series 65 optical smoke detector 55000317 apo. The xp95id is an addressable ionization duct detector that operates with gamewellfcis 600 series and ili95e3 series fire alarm control panels. This smoke detector is designed to give early warning of developing fires with an alarm sound from its builtin siren. All information in this document is given in good faith but apollo. The labyrinth is designed to exclude light from any external source. If youre in need of smoke detector installation and maintenance, please contact apollo home heating, cooling and plumbing today.
The signal increases when smoke enters the chamber and light is scattered onto the photodiode. In clear air conditions the photodiode in the xp95 detector receives no light from the led and produces a corresponding analogue signal. The chamber houses an infrared light emitting diode led. Vf2042, vf2043,and vf2044, conventional photoelectric smoke detector. Optical beam smoke detectors en542 normal sensitivity enhanced sensitivity 25.
Apollo smoke detector xp95 engineering product manual pdf. Smoke detector series 65a ionisation smoke detector series 65a heat detector the series 65a photoelectric smoke detector incorporates a pulsing led located within the housing of the detector. Manufactured making use of supreme in class material and progressive tools and technology. Apr 18, 2017 apollo alarmsense test of the smoke detector and call point with emergency lights on. It is suitable for mediumtolarge applications with simple installation requirements. Information in this catalog is given in good faith, but apollo fire detectors cannot be held. This video gives an overview of apollo xp95 detector base. The detector continuously monitors the environment for contamination of clean air by smoke particles. Xp95 optical smoke detector product eu fire and security. Apr 15, 2014 hardwired smoke alarms must be installed by a qualified professional. Ampac pty limited specialises in the design, manufacturing and technical support for a complete range of system solutions. The series 65 optical smoke detector has a moulded selfextinguishing white polycarbonate case with wind resistant smoke inlets.
Apollo alarmsense test of the smoke detector and call point. Life safety incident management ent intelligent smoke detector. Apollo smoke detectors at rs 850piece apollo smoke. Standards the xp95pdpdr, xp95ididr4 are designed to comply with the following standard.
Cb200 1 8 zone conventional control panel product profile features builtin detector removal indication facility from 1 to 8 zones 4 alarm circuits on 48 zone panels conforms to the requirements of en542 userfriendly access code oneman test facility nonlatching zone feature class change input earth fault monitoring fully functional repeater. The apollo discovery detectors are a range of highspecification, intelligent fire detectors that are developed to meet the requirements of sophisticated systems. Apollo alarmsense test of the smoke detector and call point duration. Compatible with our activ c4408d diode, c4408 nondiode and c4408r relay bases. The discovery ul ionization smoke detector uses a low activity. The xp95 optical smoke detector works using the light scatter principle and is ideal for applications where slowburning or. The apollo xp95 smoke detector uses the apollo addressing method which provides simple, user friendly and accurate identification of the apollo xp95 smoke detector location. Jun 06, 2015 this video gives an overview of apollo xp95 detector base.
View and download apollo 5357 installation manual online. When smoke enters the sensing chamber of the smoke detector, an alarm will be triggered. The xp95idr is a relay version of the xp95id, providing optional remote testing capabilities. We supply systems for a vast variety of applications including commercial and industrial buildings, mines, prisons, hospitals, hotels, and multi. Here is a picture gallery about apollo smoke detector wiring diagram complete with the description of the image, please find the image you need. Smoke detector manual sssd1 introduction the simplisafe smoke detector sssd1 is a photoelectric smoke detector, designed to sense smoke that comes into the detector chamber. Availability an ionisation smoke detector, integrating ionisation smoke detector and five grades of heat detector are available. Wiring diagram apollo smoke detector schematics and wiring diagrams inside apollo smoke detector wiring diagram, image size 650 x 459 px, and to view image details please click the image.
The apollo range is devided in the following brands. The detector is activated when smoke enters the chamber and causes an led light pulse to scatter. S65 optical smoke detector product eu fire and security. The orbis optical smoke detector operates on the wellestablished light scatter principle. Aug 27, 2019 the apollo series 65 conventional optical smoke detector uses an internal pulsing led and a photodiode at an obtuse apol,o. Apollo xp95 optical smoke detector ctec fire alarms. The detector shall operate at air velocities of 100 feet per minute to. Elite rsa, 12 loop analog addressable fire control panel. At an angle to the led is a photodiode which, in clear air conditions, does not receive light directly from the led. Requires a 45681210apo standard base or 45681242apo low power relay base. The xp95a photoelectric smoke detector works on the lightscatter principle and is ideal for applications where slowburning or smoldering fires are likely. The series 60 range of smoke and heat detectors has been extended to include intrinsically safe versions, specifically developed for use in hazardous areas. This drawing specification is the property of apollo fire detectors limited and may not be this reproduced or disclosed to a third party without the written permission of the company.
Series 65 standard ionisation smoke detector s part nos. The flexible housing of the duct smoke detector fits multiple footprints from square to rectangular. The apollo series 65 conventional optical smoke detector uses an internal pulsing led and a photodiode at an obtuse apol,o. This optical smoke detector for cfp and kentec sigma fire alarm systems is part of the apollo series 65 range.
Xp95 ionisation smoke detector xp95 ionisation smoke detector part number 55000500 operating principles the xp95 ionisation smoke detector has a moulded selfextinguishing white polycarbonate case with wind resistant smoke inlets. If smoke enters the chamber, the current flow is reduced leading to an alarm. Stainless steel wiper contacts connect the detector to the terminals in the mounting base. Established in year 2012, bharat fire engineering works is involved in manufacturing, wholesaling, retailing and service providing a huge compilation of fire extinguisher, smoke detector etc. Each brand from apollo has different key features, to meet the needs of the user.
Any orders received under the minimum order value will be returned to sender for wpollo. We have over 100 years experience serving greater cincinnati. View and download apollo 65a series installation instruction online. Wiring diagram apollo smoke detector schematics and wiring diagrams inside apollo smoke detector wiring diagram, image size 650 x 459 px, and to view image details please click the image here is a picture gallery about apollo smoke detector wiring diagram complete with the description of the image, please find the image you need. The duct unit supports two sets of form c alarm contacts and one form c trouble contact. Fire detectors ltd cannot be held responsible for any omissions or errors.
Apollo 65a series installation instruction pdf download. Smoke detector 55000886 xp95a multisensor xp95a ionisation smoke detector xp95a heat detector the xp95a ionisation smoke detector uses a low activity radioactive foil to detect fires by irradiating the air in the smoke chambers causing a current flow. Summary of contents for apollo smoke detector xp95 page 2 information in this guide is given in good faith, but apollo fire detectors limited cannot be held responsible for any omissions or errors. A highquality optical smoke detector offering outstanding detection performance at a very competitive price. Apollo alarmsense test of the smoke detector and call point with emergency lights on. The series 65 optical smoke detector incorporates a pulsing led located within the housing of the detector.
Apollo alarmsense test of the smoke detector and call. Functional test procedures for apollo smoke and heat detectors. Apollo discover detectors fire detection systems channel. Xp95 sensors xp95p addressable photoelectric smoke sensor. Smoke detector series 65a heat detector the series 65a photoelectric smoke. The detector shall operate at air velocities of 100 feet per minute to 4000 feet per minute 0. The apollo specialist environments technical manual is a detailed 198page brochure containing individual data sheets for those apollo products created for specialist environments, and has been designed for use by specifiers, designers and technicians. A copy of the declaration of conformity is available from apollo upon request. The sm501 series smoke detector is fitted with a mounting base that will. The xp95a range of analog addressable fire detectors is advanced in design and performance and offers unique features that benefit both the installer and the end user. The sl2000 series smoke duct detector is the latest innovation for early detection of smoke and products of combustion present in air moving through hvac ducts in commercial, industrial, and. The external detector moulding is identical to that of the ionisation detector but has an led which is clear in quiescent state but red in alarm. The xp95 optical smoke detector uses an internal pulsing infrared led and a photodiode at an obtuse angle. Apollo 55000650apo xp95a photoelectric smoke detector.
Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions andor increased contamination levels allowing a greater than 8 year lifespan. Orbis optical smoke detector by apollo fire detectors ltd. We are prepared to install or replace any model of photoelectric or ionization smoke detector. Each detector is addressed using apollos patented xpert card, supplied with the mounting bases. Ul standards ul standard 864 9th edition agency listings and approvals these listings and approvals apply to the modules specified in this. The apollo xp95 optical smoke detector includes a photodiode monitoring permanently the light pulse emitted by the internal led. In the fire industry, standards across the world are constantly updated and changed.